3.23 Tone Configuration
Users could configure the tone pattern of the gateway in this page. If the
disconnect tone from PSTN side is match the one of the Busy tone table, the
call will be dropped. (see figure 3.27)
Figure 3.27: Tone Configuration
Disconnect Tone – To configure the frequency, level gain and on/off time for
the busy tone from PSTN side. The busy tone supports 4 tables.
Remote Ring Back Tone –To configure the frequency, level gain and on/off
time for the ring tone from PSTN side. The gateway won’t connect the calls
if the ring tone value is incorrect.
Dial Tone – To configure the frequency, level gain and on/off time for the
dial tone.
Ring Back Tone – To configure the frequency, level gain and on/off time for
the dial tone.
This WEB Configuration is only support the FXO interface.