Dynamix DW-01Plus/H Gateway User Manual
- 55 -
Note:
For tone simulation, VoIP Gateway adopts dual frequencies as traditional
telephone does. If users want to have their own call progress tone, they can
change the valu
e of tones. High and Low frequency/level/cadence can be
configured respectively.
ringing frequency: 15 ~ 100 (Unit: Hz)
ringing ring ON/OFF: 0 ~ 8000 (Unit: ms)
ringing level: 0 ~ 94 (Unit: V)
tone frequency: 0 ~ 65535 (Unit: Hz)
tone freqLevel: 0 ~ 65535 (Unit: mVrms)
tone Tone ON/OFF: 0 ~ 8000 (Unit: ms)